ProxMox: Difference between revisions
No edit summary |
|||
Line 57: | Line 57: | ||
__TOC__ | __TOC__ | ||
== Hardware == | == Hardware == | ||
<p>The server base is a Dell T320 bought on ebay.</p> | |||
* Dell T320 | * Dell T320 | ||
* 2x400GB Intel SSD DC S3700 | * 2x400GB Intel SSD DC S3700 | ||
Line 64: | Line 65: | ||
* 1xH310 Perc Card (HBA modded) | * 1xH310 Perc Card (HBA modded) | ||
* 2x495W PSU | * 2x495W PSU | ||
=== SSD (Raid1) === | |||
<p>Two Intel DC S3700 (400GB) Enterprise-SSD where bought and installed internal running in Raid1 where ProxMox and the VMs/LXCs are installed.</p> | |||
=== RAID-Controller === | |||
=== CPU === | |||
<p>Originally the CPU Intel was installed but since the hardware is already a bit old it is possible to buy it cheap.</p> | |||
<p>I decided to install the best availaible CPU for the Socket ???? which is the [https://ark.intel.com/content/www/de/de/ark/products/75266/intel-xeon-processor-e5-2470-v2-25m-cache-2-40-ghz.html Intel Xeon E5-2470V2 2.40GHz 10-Core 25MB].</p> | |||
=== Fan === | |||
<p>At the beginning the original fan was use because it was quiet enough, but after installing the HHDs it got really loud</p> | |||
<p>It seems the mainboard adjust the fan according to the amount of PCIE-devices installed and it is not possible to change much of the fans behaviour</p> | |||
<p>The only solution was to replace the fan with an more quiet one, so the [https://noctua.at/de/nf-a12x25-pwm Noctua NF-A12x25] got installed.</p> |
Revision as of 21:28, 21 February 2021
IP: | 192.168.88.6 192.168.88.7 |
---|---|
MAC: | 20:47:47:82:E0:BA 20:47:47:82:E0:BC |
Domain: | ve.flowerhouse.at |
OS: | ProxMox |
---|---|
RAM: | 96GB |
Cores: | 10/20 |
ProxMox is reachable under 192.168.88.6:8006
which is located in the ServerVLAN.
The subdomain is ve.flowerhouse.at which is handled by the ReverseProxy.
List of servers running on ProxMox:
Name | Domain | Address | Type |
---|---|---|---|
TrueNAS | nas.flowerhouse.at | 192.168.88.5 | VM |
Reverse-Proxy | 192.168.88.9 | LXC | |
NextCloud | cloud.flowerhouse.at | 192.168.88.10 | LXC |
FHEM | home.flowerhouse.at | 192.168.88.11 | LXC |
Heater | heater.flowerhouse.at | 192.168.88.12 | LXC |
DataBase | db.flowerhouse.at | 192.168.88.13 | LXC |
MediaWiki | wiki.flowerhouse.at | 192.168.88.14 | LXC |
Hardware
The server base is a Dell T320 bought on ebay.
- Dell T320
- 2x400GB Intel SSD DC S3700
- 4x3TB HDD
- 96GB ECC-RAM
- Intel Xeon E5-2470V2 2.40GHz 10-Core 25MB
- 1xH310 Perc Card (HBA modded)
- 2x495W PSU
SSD (Raid1)
Two Intel DC S3700 (400GB) Enterprise-SSD where bought and installed internal running in Raid1 where ProxMox and the VMs/LXCs are installed.
RAID-Controller
CPU
Originally the CPU Intel was installed but since the hardware is already a bit old it is possible to buy it cheap.
I decided to install the best availaible CPU for the Socket ???? which is the Intel Xeon E5-2470V2 2.40GHz 10-Core 25MB.
Fan
At the beginning the original fan was use because it was quiet enough, but after installing the HHDs it got really loud
It seems the mainboard adjust the fan according to the amount of PCIE-devices installed and it is not possible to change much of the fans behaviour
The only solution was to replace the fan with an more quiet one, so the Noctua NF-A12x25 got installed.